Two Phase Flow Regime Determination
![]()
| The two phase flow regime determination procedure presented here applies to steady-state, isothermal two phase pipe flow of incompressible Newtonian fluids. The procedure is based on Baker's flow regime maps. | |
| For your convenience, The input form below has several multiple choice fields {using radio buttons} with one field already selected as default. Please make sure that you always mark the proper button corresponding to your input if it is different from the default. |
![]()
| Gas / Vapor Flowrate | ||
| Mass Basis | ||
| Volume Basis | ||
| Superficial Velocity Basis | ||
| Mass Velocity Basis | ||
|
||
| Gas / Vapor Physical Properties | ||
| Density | ||
|
||
| Liquid Flowrate | ||
| Mass Basis | ||
| Volume Basis | ||
| Superficial Velocity Basis | ||
| Mass Velocity Basis | ||
|
||
| Liquid Physical Properties | ||
| Density | ||
| Viscosity | ||
| Surface Tension | ||
|
||
| Piping | ||
| Diameter | Nominal, inches (1) | Schedule(3) |
| Inside / equivalent | ||
|
||
| Report: | ||
Flow regime and include |
||
|
||
![]()
![]()
Copyright © 1996, Process Associates of America. All Rights Reserved.